Compact type remote mass flowmeter EMIS-MASS 260
- Product description
- Documentation and software
- Technical parameters
- Certificates
- Сomplete set
- Presentations
Download data sheet configuration
The transmitter of EMIS-MASS 260 is installed in the distance from the pipeline. The cable connects the transducer and the transmitter. The cable length should not exceed 100 meters.
Features & Benefits of Compact remote type of Coriolis mass flowmeter:
- Remote indication;
- Compact size;
- Easy installation in any section;
- Resistance to vibrations of industrial frequencies;
Medium temperature: -60°С … 200°С
To order products, please, call: +7 (351) 729-99-13 or fill in a questionnaire with a description of the process. Our specialists provide you a detailed technical and commercial offer.
-
ATEX certificate EMIS-MASS 260
Parameter | Description |
Medium |
|
Flow range | See table Flow Range |
Accuracy |
±0,1%, ±0,15%, ±0,25%, ±0,5% |
Pipeline Dn liquids/gases | 10 to 200 mm / 10 to 100 mm |
Medium pressure | Up to 25 MPa |
Medium temperature | -60°С … +200°С |
Output signals |
|
Explosion protection |
|
Ambient temperature | -60°С до +70° |
Ingress protection | IP66 / IP67 |
Calibration interval |
5 years |
-
SIL2 certificate
-
Certificate of Recognition by the River Register. EMIS-DIO 230, EMIS-PLAST 220, EMIS-MASS 260, EMIS-VEKTA 1210/1215
-
Manufacturer Recognition Certificate of the Russian Maritime Register
-
Declaration of Conformity for «Electromagnetic compatibility»
-
Certificate of vibration resistance. EMIS-MASS 260
-
Certificate of Software Copyright Registration EMIS-MASS 260
-
Certificate of Conformity for «Electromagnetic compatibility»
-
The Customs Union Certificate of Conformity ТR CU 012 “On the safety of equipment applied in hazardous area”. EMIS-MASS 260
-
Certificate of Conformity "On the safety of low-voltage equipment"
-
TR CU 010/2011 "On Safety of Machinery and Equipment". EMIS-MASS 260
-
Declaration of Conformity "On the safety of low-voltage equipment"
-
Declaration of Conformity TR CU 032 “On safety of equipment operating under excessive pressure”
-
Type approval certificate. EMIS-MASS 260
-
Type approval license by Russian River Register. EMIS-DIO 230, EMIS-PLAST 220, EMIS-MASS 260
-
Approval for food application. EMIS-MASS 260
-
Type approval license by Maritime Register. EMIS-DIO 230, EMIS-PLAST 220, EMIS-MASS 260
-
Type approval certificate by Russian River Register. EMIS-DIO 230, EMIS-PLAST 220, EMIS-MASS 260
-
Certificate of Conformity GOST R 53679-2009, GOST 53678-2009. EMIS-MASS 260
The cost of the flowmeter depends on the configuration.
|
||||||
|
||||